Long time used High temperature and high pressure cleaning machine Possible problems
 
1) spray gun does not spray water:
 
A) the water inlet and water inlet filter are blocked. b) Nozzle clogging. c) The heating spiral tube is blocked and the scale is removed if necessary.
 
2) unstable outlet pressure:
 
A) lack of water supply. b) The air suction pipeline was formed due to the cracking of the pipeline and the cleaner nozzle not penetrating into the cleaner. c) Nozzle wear. d) High pressure water pump seal leakage.
 
3) the incinerator does not burn
 
A) lack of air intake and white smoke. b) The fuel filter, fuel pump and fuel nozzle are dirty and blocked. d) The solenoid valve is damaged. e) The orientation of the incineration electrode is changed, and the spark is too weak. f) High pressure incineration coil is damaged. g) Pressure switch hazard.
 
High temperature and high pressure cleaning machine has the above problems, users can find out the causes and eliminate the problems. However, in case of serious defects such as pump leakage and crankcase oil leakage, the cleaning machine should be sent to the professional repair part with complete accessories and strong technical force to avoid unnecessary economic loss.